BESFULTemperature difference and return water control module class

BF-D215B + Microcomputer Temperature Difference Controller

BF-D215B+ Differential Temperature Controller is mainly used in solar forced circulation,Hot water circulation, return water system control, etc.,Can detect the temperature difference between [high-temperature point T1] (e.g., collector) and [low-temperature point T2] (e.g., water tank),When the [temperature difference] reaches the user's preset value,Automatically activates the relay output to control loads such as the [circulation pump], circulating hot and cold media between high- and low-temperature points,Thereby reducing the temperature difference between the high- and low-temperature zones (referred to as the temperature differential).
Export SupportContact our Export Department for specifications, quotations, samples and shipping arrangements.

Product Details

BF-D215B+ Differential Temperature Controller is mainly used in solar forced circulation,Hot water circulation, return water system control, etc.,Can detect the temperature difference between [high-temperature point T1] (e.g., collector) and [low-temperature point T2] (e.g., water tank),When the [temperature difference] reaches the user's preset value,Automatically activates the relay output to control loads such as the [circulation pump], circulating hot and cold media between high- and low-temperature points,Thereby reducing the temperature difference between the high- and low-temperature zones (referred to as the temperature differential).

The water tank temperature sensor probe is waterproof and can be immersed directly in high-temperature water for measurement.

Compact size and fast track mounting design.The switching power supply ensures stable, reliable, and continuous controller operation as the supply voltage varies between AC80V~240V.

Application Scenario 1: Solar Thermal Collection Thermal Difference Cycle Application

Controls the start/stop of the temperature-difference circulation pump to exchange hot and cold water between the collector and tank, gradually heating the tank water.

Scenario 2: Return water insulation system

control return water solenoid valve for pipeline antifreeze

<video autoplay="autoplay" controls="controls" controlslist="nodownload" height="600" loop="loop" src="https://video.wezhan.cn/701806afb1c571eeb3506733a78e0102/9947894a9b7b47459a558704796b40f4-28277d271fc4836c983fba22a82f821d-sd.mp4?auth_key=1705117372-9c9c184e3458476c8d08af10d9eb3306-0-45a5b30afb45089908464e8565b3b1cd" title="Product

Product key features

  • Installation and features

  • 1. Measures the temperature difference between two points and activates one relay output when the set positive differential is reached

  • 2. Relay output normally open, normally closed point

  • 3. Press F1 to independently view the temperatures at the high- and low-temperature points

  • 4. Temperature values measured at high and low temperatures can be manually corrected

  • 5. High-precision NTC 10K temperature sensor ensures stable and reliable measurement

  • 6. Long-distance temperature sensor measurement (100 m) requires no compensation

  • 7. Setting parameters Power off Permanent memory retention

  • 8. Standard DIN rail mounting, compact size, easy installation

  • 9. Powered by a switching power supply for stable operation at AC80-240V

Typical Product Applications

Product Technical Parameters

Rated voltage AC80~240V 50/60HZ
Power Consumption 3 Watts
Ambient temperature -10~55℃
Ambient humidity 35~85%RH
Display mode Digital Module
Input T1, T2 (NTC 10K Thermistors, B=3435K)
Measurement range -50~150℃
Measurement accuracy 0.5FS%
Temperature Drift ±0.3FS%
Control output ON/off relay switch
Relay Contact Load Capacity 1. Resistive load: 5A, 250VAC; supports equipment up to 1250W
2. Inductive load: 1A, 250VAC; supports equipment up to 150W
3. If the load current is >5 A (resistive) or >1 A (inductive), an AC contactor must be used for switching.
Extension wire The sensor cable can be extended up to 100 m using wire
Power-off memory Long-term memory retention function with power down setting parameters

Product packaging, specifications and weight

Appearance dimension (mm) Length 91 × width 40 × height 52 mm
Installation Dimensions Panel cutout mounting, cutout size 51 × 71 mm
Weight Gross weight 184.5 g
Net Weight 154.5g
↑