BF-170MW is a full-featured hot-water system controller in which one main unit controls the entire system. Two control panels (wired remote controllers) can be connected in series at the user end for remote adjustment of the main unit.
The product integrates three function groups: water-filling control (low-water filling, temperature-controlled filling, timed filling, and manual filling), heating control (timed auxiliary heating, heat-collection circulation, and manual heating), and return-water control (timed and manual return water), covering various hot-water system control requirements.
The installation position of the [Water Inlet Valve] determines the system's water-filling mode. Through parameter settings, users can select cold-water inlet at the collector or cold-water inlet at the tank.
BF-170MW is especially suitable for centralized hot-water control in villas, resort hotels, guesthouses, and similar facilities, meeting high-volume water-heating demands with stable, outstanding performance.
Get a quick overview of product features and applications
BF-170MW supports 1–4 additional wired remote controllers installed in different locations as needed. Four remote controllers are connected in series using HX2.54-3P data communication cables and then connected to the main unit, creating a more convenient control system.
T1. Water tank temperature sensor input:
T2. Heat collector plate temperature sensor input;
T3. Pipe insulation temperature sensor input;
W1. Water level sensor input.
Output
◆ Electric heating output, load power AC220V, 3KW;
◆ Differential temperature circulation pump output, rated load: AC220V, 200W;
◆ Pipeline circulation pump (or water pressure booster pump) output, load rating AC220V, 200W;
◆ Water supply booster pump output, rated load: AC220V, 200W
Timing Clock
24-hour clock
Timing range
00:00 - 23:59 (hours: minutes)
Measurement range
Temperature range: -19 to 99°C
Water level measurement range: 0%, 20%, 50%, 80%, 100%
Set Range
Heating temperature setting: 0 ~ 85 ℃
Full-tank water level setting range: 50%, 80%, 100%
Control Range
Heating temperature control range: 0 ~ 85 ℃
Full-tank water level setting range: 50%, 80%, 100%
Other Parameters
The temperature sensor cable can be extended up to 100 m using ordinary wire
Setting parameters Power down Long-term memory retention
Temperature control Water temperature control range: 10 ~ 80 ℃
Temperature difference control range of the heat collecting plate: 4 ~ 30 ℃
Tank temperature range for stopping differential-temperature circulation: 55~99℃
Temperature control range: 20 ~ 50 ℃
Antifreeze cycle temperature control range: -10 ~ 10 ℃
Typical Product Applications
Product Technical Parameters
| Operating Power and Power Consumption |
Operating power: AC80–240V, 3 W Standby power: <2 W |
| Usage environment |
-10℃~50℃ |
| Display mode |
Led digital display |
| Button |
Push-type silicone keys |
| Input |
Three 10K NTC thermistor temperature inputs and one water tank level sensor input: ●T1. Water tank temperature sensor input: ●T2. Heat collector plate temperature sensor input; ●T3. Pipe insulation temperature sensor input; ●W1. Water level sensor input. |
| Output |
◆ Electric heating output, load power AC220V, 3KW; ◆ Differential temperature circulation pump output, rated load: AC220V, 200W; ◆ Pipeline circulation pump (or water pressure booster pump) output, load rating AC220V, 200W; ◆ Water supply booster pump output, rated load: AC220V, 200W |
| Timing Clock |
24-hour clock |
| Timing range |
00:00 - 23:59 (hours: minutes) |
| Measurement range |
Temperature range: -19 to 99°C Water level measurement range: 0%, 20%, 50%, 80%, 100% |
| Set Range |
Heating temperature setting: 0 ~ 85 ℃ Full-tank water level setting range: 50%, 80%, 100% |
| Control Range |
Heating temperature control range: 0 ~ 85 ℃ Full-tank water level setting range: 50%, 80%, 100% |
| Other Parameters |
The temperature sensor cable can be extended up to 100 m using ordinary wire Setting parameters Power down Long-term memory retention Temperature control Water temperature control range: 10 ~ 80 ℃ Temperature difference control range of the heat collecting plate: 4 ~ 30 ℃ Tank temperature range for stopping differential-temperature circulation: 55~99℃ Temperature control range: 20 ~ 50 ℃ Antifreeze cycle temperature control range: -10 ~ 10 ℃ |
Product packaging, specifications and weight
| Product Packaging List |
1. 1 mainframe, 2. Three NTC 10K temperature sensing lines; 3. Instructions; |
| Appearance dimension (mm) |
160 (length) × 112 (width) × 40 (thickness) |
| Installation and dimensions (mm) |
Wall-mounted installation |
| Weight |
Net Weight: 0.545Kg Gross weight: 0.684Kg |