D-615 is a solar hot-water project controller widely used in solar + heat-pump hot-water systems. Its powerful functions include heat-collection circulation, low-water filling, timed and temperature-controlled water filling, timed tank auxiliary heating, and constant-temperature return water, meeting diverse customer requirements.
The controller's switching power supply supports AC80V~240V input and ensures stable, reliable, and durable operation, guaranteeing controller stability and reliability.
● Function 1: Solar Thermal Cycle
● Feature 2: Lack of running water
● Function 3: Fixed temperature water three times a day
● Function 4: Heating three times a day at regular intervals
● Function 5: Temperature return water
● Both heat-collection circulation and electric heating use high-current relay outputs. The heat-collection circulation output can directly drive a 500W pump, and the tank constant-temperature heating output can directly drive a 2000W electric heater.
● The collector temperature probe uses an NTC230K thermistor with a high-temperature-resistant design, withstanding temperatures up to 250°C
● The water tank temperature probe uses a waterproof sensor and can be immersed directly in water for temperature measurement.
● Temperature measurements for the collector, water tank, and other thermostats are all displayed to one decimal place
● Fault alarms: temperature measurement fault alarm and water level fault alarm
● Three-way temperature measurement deviation correction
● Intelligent power supply design automatically adapts to AC80V–240V, ensuring stable, durable operation worldwide.
Product Technical Parameters
| Operating power supply |
AC80~240V,AC/50HZ/60HZ |
| Power Consumption |
works 5 watts, standby < 2 watts |
| Storage Environment |
40℃~70℃;5% to 95% non-condensing |
| Work environment |
0℃~40℃;10% to 90% non-condensing |
| Display mode |
Digital Module |
| Buttons |
Silicone buttons |
| Temperature sensor |
High-temperature sensor T0: thermistor R(25℃)=230KΩ±1% B(100/200℃)=4537K±1%.
Standard temperature sensors T1, T2: thermistor R(25°C)=10KΩ±1%, B=3435 |
| Temperature Measurement Range |
Collector Panel Temperature Sensor T0: -20.0 to 250.0°C
Tank temperature sensor T1: -20.0~150.0℃
Temperature control sensor T2: -20.0~150.0℃ |
| Show resolution |
±0.1℃ |
| Measurement accuracy |
±1℃ |
| Output power |
OUT1: Channel 1 collector circulation pump live-wire output, 20A/250VAC, directly controlling a 500W temperature-difference circulation pump
OUT2: Channel 2 water-supply live-wire output, 20A/250VAC, directly controlling a 500W pump (or water-supply solenoid valve)
OUT3: Channel 3 constant-temperature water tank live-wire output, 5A/250VAC, controlling resistive electric heating loads
OUT4: constant-temperature return-water live output, 5A/250VAC, controls a return-water solenoid valve |
| Other |
Flash memory technology retains parameter settings for extended periods after power loss |
Product packaging, specifications and weight
| Exterior dimensions |
100mm (Length) x 100mm (Width) x 70mm (Height) |
| Net Weight |
301.5g |
| Gross Weight |
409 g |