BESFULWater level control module class

EV3 Single Tank Water Level Controller

EV3 can be used in four different applications, making it a truly versatile, fully automatic controller.Used with BESFUL three-wire water-level sensors for fully automatic water filling, pumping from wells to storage tanks, automatic drainage based on reservoir levels, automatic basement flood drainage, temperature-controlled heating with dry-burn protection, and many other applications.DIN rail design for easy installation and maintenance, with simple single-button operation.
Export SupportContact our Export Department for specifications, quotations, samples and shipping arrangements.

Product Details

EV3 can be used in four different applications, making it a truly versatile, fully automatic controller.Used with BESFUL three-wire water-level sensors for fully automatic water filling, pumping from wells to storage tanks, automatic drainage based on reservoir levels, automatic basement flood drainage, temperature-controlled heating with dry-burn protection, and many other applications.DIN rail design for easy installation and maintenance, with simple single-button operation.

Standard DIN rail mounting with a plug-in base for easy replacement; compact design

A manual water supply button allows temporary refilling for easy commissioning and adjustment.

Upper and Lower Limit Liquid Level Control (Purpose 1)

pumping and drainage control (use II)

single level water control (use three)

Water supply and heating anti-dry combustion control (use 4)

Product Technical Parameters

Rated voltage AC220V±10%, power consumption &le;2 W, standby power <2 W
Usage environment Storage: 40°C ~ 70°C;5% to 95% non-condensing;Working environment: 0 ℃ ~ 40 ℃;10% to 90% non-condensing
Installation method Standard DIN-rail mounting or screw-fixed mounting (4 mm holes spaced 34 mm apart)
Display mode Led indicator
Buttons Used for manual forced watering, manual forced stop watering
Inputs Three signal inputs are provided: A, B, and C. A is the full-tank level electrode input, B is the tank refill-level electrode input, and C is the common electrode.
Control Range Monitor the upper and lower liquid levels
Control output Relay suction/disconnection
Relay Load Capacity Normally open contact: current rating 10A/250VAC
Normally closed contact: current rating 10A/250VAC
Extension wire Sensor cables can be extended up to 100 m with wires; do not route them in the same conduit as high-voltage power cables

Product packaging, specifications and weight

Overall Exterior Dimensions Length 41mm × Width 50mm × Height 96mm (Including Socket)
Gross weight/net weight G.W.: 233.5g / N.W.: 199.5g
↑