ꁆ ꁇ
BESFULTemperature difference and return water control module class

D-F228 + Temperature Controller

D-F228+ Differential Temperature Controller is mainly used in solar forced circulation,Hot water circulation, return water system control, etc.,Can detect the temperature difference between a [high-temperature point] (e.g., collector) and a [low-temperature point] (e.g., water tank),When the [temperature difference] reaches the user's preset value,Automatically activates the relay output to control loads such as the [circulation pump], circulating hot and cold media between high- and low-temperature points,Thereby reducing the temperature difference between the high- and low-temperature zones (referred to as the temperature differential).
Export SupportContact our Export Department for specifications, quotations, samples and shipping arrangements.

Product Details

D-F228+ differential-temperature controller is mainly used in forced solar circulation, Hot water circulation, return water system control, etc.,Can detect the temperature difference between a [high-temperature point] (e.g., collector) and a [low-temperature point] (e.g., water tank),When the [temperature difference] reaches the user's preset value,Automatically activates the relay output to control loads such as the [circulation pump], circulating hot and cold media between high- and low-temperature points,Thereby reducing the temperature difference between the high- and low-temperature zones (referred to as the temperature differential).

Compact size and fast track mounting design.

Product key features

  • Measures the temperature difference between two points and activates one relay output when the set positive differential is reached

  • Relay output normally open, normally closed point

  • Press F1 to independently view the high- and low-temperature readings

  • High-temperature, low-temperature measured temperature values can be manually corrected

  • Setting parameters Power-off memory function

  • High-precision NTC 10K temperature sensor for stable, reliable measurement

  • Long-distance temperature measurement (100 m) requires no compensation

  • Standard rail mounting, tiny size, easy installation

  • Switching power supply for stable operation at AC80~240V

Product Technical Parameters

Rated voltage AC220V
Power Consumption 3W, standby
Ambient temperature -10~55℃
Ambient humidity 35~85%RH
Display mode Three-digit led digital display, display resolution: 1 ℃
Input Temperature Sensors T1, T2 (NTC10K Thermistors, B=3950K)
Temperature Measurement Range Temperature measurement error: 1%; temperature measurement range: 50~150℃
Temperature difference measurement range 99~200℃
Temperature difference control range 0~60℃
Output and power One NO/NC contact output rated at 6 A for resistive loads and 1 A for inductive loads.Can control a 1000W electric heater or a 100W motor or pump; larger loads require an AC contactor
Other
Installation method Can be mounted on a standard DIN rail or a fixed base; the fixed-base mounting holes are spaced 84 mm apart

Product packaging, specifications and weight

Appearance dimension (mm) 91 (L) x 40 (W) x 52 (H)
Weight 211 g (net)
2.290 g (gross)
↑