C3-15B+ Upper/Lower Limit Differential Temperature Controller

C3-15B+ Upper/Lower-Limit Temperature Difference Controller, mainly used in hot water circulation and return-water system control.
Export SupportContact our Export Department for specifications, quotations, samples and shipping arrangements.

Product Details

C3-15B+ Upper/Lower-Limit Temperature Difference Controller, mainly used in hot water circulation and return-water system control.

It intelligently detects the temperature difference between a [High-Temperature Point (e.g., collector)] and a [Low-Temperature Point (e.g., tank)]. When the [Temperature Difference] reaches the user's preset value, a relay output automatically activates a [Circulation Pump] or other load to circulate the high- and low-temperature media for heat exchange, reducing the temperature difference (abbreviated as "differential temperature") between the two zones.

BF-15B+ is designed to activate only on a positive temperature differential; a negative differential will not activate the output. Very easy to operate: simply adjust the upper and lower differential temperature limits to implement control.

The wide-range power supply automatically adapts to AC80V–240V for stable, reliable, long-term operation.

Product key features

  • Two 240K NTC temperature sensor inputs

  • Normally open and normally closed output all the way

  • Temperature difference cycle function

  • Temperature difference display

  • Temperature measurement deviation correction function

  • Power-off memory protection function

Typical Product Applications

Product Technical Parameters

Operating Power and Power Consumption AC(80~240)V,2W
Usage environment -10℃~50℃
Display mode Led digital display
Button Push-type membrane buttons
Input Two 240K NTC thermistor temperature sensor inputs, measurement range -20°C to 120°C
Output 1. One relay with normally open and normally closed contacts controls differential-temperature circulation
2. The output contact is rated at 6A for resistive loads and 1A for inductive loads.
Can control a 1000W electric heater or a 200W motor or pump; larger loads require an AC contactor
Measurement range -99~120℃
Set Range 0~60℃
Control Range 0~60℃
Other Parameters 1. The temperature sensor signal cable can be extended with ordinary wire for long-distance use, up to 100 m.
2. Parameter settings are retained long-term after power loss. 3. Temperature control differential: 0°C to 30°C.

Product packaging, specifications and weight

Product Packaging List 1. Host  2. NTC (240K) temperature sensor cables (2 pcs.)  3.User Manual  4.Mounting Bracket
Appearance dimension (mm) L 72 x W 72 x D 60
Installation and dimensions (mm) Window mount with 68 × 68 openings
Weight Net weight: 0.204Kg; gross weight: 0.264Kg
↑